6/30/2023 0 Comments Triad aer 2.0 manual![]() Under maximum power settings and rated load conditions, the ForceTriad energy platform is capable of operating a duty cycle of 25% defined as 10 seconds active and 30 seconds inactive, in any mode for a period of 4 hours.Keying delay: User selectable in 500 msec increments from 0 sec to 2.5 sec.± 5% of Full-Scale activation impedance while keying inactive.+ 50%, -14% of full-scale activation impedance while keying active at 10 watts or below.Measurement accuracy: ± 14% of Full Scale activation impedance while keying active above 10 watts.Deactivation impedance: User selectable: 1,500 Ω 1,800 Ω or 2,200 Ω.Interrogation frequency: 80 kHz ± 10 kHz.Note: The autobipolar electrode function requires the use of the Valleylab E0018 bipolar Instrument cord.The ForceTriad energy platform is equipped with an autobipolar feature that allows for the automatic activation of bipolar energy.Then, the indicator illuminates green and RF output is enabled. The indicator remains illuminated red and yellow until you correct the condition causing the alarm. REM patient return electrode: When the measured resistance exceeds the standard range of safe resistance (below 5 ohms or above 135 ohms) or when the initially measured contact resistance increases by 40% (whichever is less), the REM alarm indicator enlarges and flashes red and yellow, a tone sounds twice, and RF output is disabled.If the measured resistance is outside the acceptable range(s) noted above, a REM fault condition occurs.REM patient return electrode: 5 to 135 ohms or up to a 40% increase in the initial measured contact resistance (whichever is less).REM resistance measurements are ± 10% during RF activation and ± 5% when RF output is not activated.Error/System Alert: Two 1/2 second tones separated by 1/2 second for each Error/ System Alert event.Check Instrument: Six 175 msec tones – high, low, high low, high, low -Seal Complete: Two 175 msec tones separated by 175 msec for each Seal Complete event.Reactivate/Regrassp: Four 175 msec tones-high, low, high–low separated by 1/2 second. ![]() REM: Two 1/2 second tones separated by 1/2 second for each REM event.Error/System Alert: Beep tone = 1400 Hz.Regrassp: Two tones: High= 985 Hz, Low = 780 Hz.Duration: Continuous while the system is activated.The audio levels stated below are for activation tones (cut, Valleylab, coag, bipolar, and LigaSure Modes) and alarm tones (REM and system alarms) at a distance of one meter.Any Stable, flat surface such as a table or cart top.Mounting cart (UC8009), and/or the UC8010 Over-shelf.ForceTriad energy platform cart (FT900) Universal.Connector ports: LED illuminated Smart connector readers. ![]()
0 Comments
Leave a Reply. |